Avaliação da desadaptação vertical de cilindros protéticos a pilares esteticone variando a técnica de moldagem e inclinação dos implantes
Evaluation of vertical misfit at prosthetic cylinder/estheticone abutment interface varying impression technique and implant angulation |
| |
| Autores |
| |
Miguel Angelo Nadin* Paulo Sergio Nadin** Milton Edson Miranda*** Carlos Alberto Muzilli*** Marcelo Lucchesi Teixeira*** |
| |
| Resumo |
| |
O objetivo deste estudo foi avaliar a desadaptação marginal da interface entre intermediário esteticone e cilindros metálicos pré-usinados de titânio, por meio de análise com microscopia óptica, variando a angulação dos implantes e a técnica de moldagem. Para isto foram confeccionadas duas matrizes metálicas, contendo dois implantes cada, posicionados em uma delas paralelos entre si e na outra angulados 20º entre si. As técnicas de moldagem de transferência usando Poliéter (Impregum) foram: moldagem com moldeira aberta com transferentes quadrados unidos com resina acrílica Duralay e moldagem com moldeira fechada com transferentes cônicos. Foram confeccionados cinco moldes para cada um dos quatro grupos. Grupo I - moldagem com moldeira aberta e implantes dispostos paralelos entre si, utilizando transferentes quadrados. Grupo II - moldagem com moldeira aberta com implantes inclinados 20º entre si, utilizando transferentes quadrados. Grupo III - moldagem com moldeira fechada com implantes dispostos paralelos entre si, utilizando transferentes cônicos. Grupo IV - moldagem com moldeira fechada com implantes inclinados 20° entre si, utilizando transferentes cônicos. Os dados foram coletados através de microscopia óptica (Digital Microhardness Tester HVS - 1.000) mensurando quatro pontos de desadaptação em cada corpo de prova. Após tabulados, foram analisados pela análise de variância (Anova) e pelo teste de Tukey (p < 0,05). Não houve diferença estatisticamente significante entre os grupos (I e II) e (III e IV). Avaliando as técnicas de moldagem sobreimplantes paralelos entre si, não houve diferença estatisticamente significante entre os grupos (I e III). Avaliando as técnicas de moldagem sobreimplantes inclinados entre si (I e IV), houve diferença estatisticamente significante entre as mesmas. As técnicas de moldagem com moldeira aberta apresentaram menores valores de desadaptação.
Unitermos - Desadaptação marginal; Técnica de moldagem odontológica; Implantes dentários. |
| |
| Abstract |
| |
The aim of this study was to evaluate the margin misfit at the interface between estheticone abutments and pre-machined metal cylinder titanium abutment through optical microscopy, varying implant angulation and impressiontechniques. Two metallic matrices containing with two implants each, placed in one of them parallel to each other and in the other one angled 20 from each other, were used in this study. Impression transfer techniques using a polyether material were: impression transfers with open tray with square transfer copings splinted with Duralay acrylic resin, and impression with closed tray and conical transfer copings. Five impressions were made for each of the four groups. Group I - open tray obtained from the master cast with implants arranged parallel to each other using square transfers. Group II - open tray obtained from the master cast with tilted implants 20o between them, using square transfers. Group III - closed tray obtained from the master cast with implants arranged parallel to each other using conical transfers. Group IV - closed tray obtained from the master cast with tilted implants 20o to one another using conical transfers. Data was collected through an optical microscope (Digital Microhardness Tester HVS-1000) measuring four points of adaptation in each sample. Data was analyzed using the variance test (Anova) and Tukey test at the 5% level of significance. There were no statistically significant differences between the groups (I and II), and (III and IV). Analyzing the impression transfer techniques on parallel implants, there were no statistically significant differences between groups (I and III). Analyzing the impression transfer technique with implants inclined to each other (groups II and IV), there were statistically significant differences. The open tray technique using square transfer copings (Group I) showed small values of misfit.
Key Words - Margin fit; Dental impression techniques; Dental impression materials. |
| |
* Mestre em Prótese Dentária - Centro de Pesquisas Odontologicas São Leopoldo Mandic - Campinas/SP; Especialista em Implantodontia - Cela - Unilavras/MG. ** Mestre e doutor em Prótese Dentária - Unicamp - Piracicaba/SP; Professor dos Cursos de Implantodontia e Prótese Dentária - Unicsul - Odontocenter - Passo Fundo/RS. *** Professores doutores do curso de Mestrado em Prótese - Faculdade de Odontologia Centro de Pesquisas Odontológicas São Leopoldo Mandic - Campinas/SP. |
|
|
|
| |
|
|
|
|
|
|
|